    Detection method of common faults of medium frequency electric furnace

    2021-11-29 1852

      1. First, observe whether the indication values of the four small meters in the if cabinet are normal. The rectifier operated voltmeter is 30V, the rectifier pulse ammeter is 130 ~ 150mA, the inverter operated voltmeter is 12V, and the inverter pulse ammeter is 100 ~ 120mA. If the value is within the normal range, it proves that there is no problem with the power supply part.

      2. Check the anode, cathode resistance, control electrode and cathode resistance of rectifier and inverter thyristor with the digital multimeter in 2008 (it is not necessary to remove it from the cabinet for measurement, and there is still cooling water in the pipe radiator). The positive and negative resistance values of anode and cathode are ∞, and the resistance values of control electrode and cathode are 10 ~ 508. In addition, check whether the fuse is blown.

      3. Place the change-over switch SA in the viewing gear, use an oscilloscope to check the waveform of rectifier and inverter trigger pulse, and check whether the amplitude and time interval are normal. In the meantime, the rectifier trigger pulse is double pulse, and the time interval is 3.33ms; The inverter trigger pulse is a continuous pulse train, and the amplitude is generally 4 ~ 6V. The pulse shall be neat and free of burrs. The viewing order is from the thyristor control pole to the pulse transformer, and then to the rectifier board and inverter board.

      4. Check whether the rectifier board is normal. The inverter board can be unplugged and the change-over switch can be placed in the viewing gear. Press the start button and turn the power regulating potentiometer to see if the DC voltage can be adjusted to about 500V. If the voltage can be adjusted to 500V, it proves that the rectifier board is normal.

      5. Check the capacitor charging circuit in the engine circuit. Still unplug the inverter board and turn on the viewing gear. After pressing the start button, measure the voltage at both ends of the capacitor CF with a multimeter. If it can reach about 500V, it proves that the charging circuit of the starting capacitor is normal.

      6. Check whether the pre magnetization resistance R6 is burnt out and whether the low-pass filter is broken.

      7. If the above checks are normal, the fault can basically be the load part of the autonomous circuit. At this moment, you can check whether the capacitor has obvious burn marks or severe oil leakage, whether the insulation of the capacitor support to the ground is about 2m8, whether the water-cooling cable is burnt out, and whether the measuring induction ring has short circuit to the ground and between turns (generally caused by molten iron leakage of the furnace lining). When the induction coil is connected with water, its resistance to ground shall be more than 5k8, and the insulation resistance of the induction coil to the yoke shall be about 2m8 (when the yoke is not grounded).

      8. After checking, if it is considered that the medium frequency power supply cabinet is normal, the capacitor is normal, the insulation of the induction coil and yoke meets the requirements after intermediate repair, and the furnace lining is newly built, and there is still overcurrent phenomenon in power transmission, it can be that the thermal state characteristics of an inverter thyristor are poor, that is, in the case of no power transmission, its characteristic data are normal, However, after power transmission, due to heating, there is a forced positive turn, resulting in overcurrent. At this moment, the inverter tubes should be replaced one by one to see if there is still overcurrent.

      Article from:http://www.oavoav.cn

    主站蜘蛛池模板: 国产实拍强伦奸在线观看| 久久天天躁夜夜躁狠狠I女人| 亚洲不卡视频一区二区三区| 国产真实乱人偷精品视频| 日韩欧美精品一中文字幕| 国产精品青青青高清在线| 国内精品91久久久久| 国产蜜芽尤物在线一区| 勐海县| 亚欧乱色精品免费观看| semimi亚洲综合在线观看| 岳池县| 国产在线无码av完整版在线观看| 日本一区中文字幕最新在线| 日韩一区二区三区无码人妻视频| 鲁鲁鲁爽爽爽在线视频观看| 黄网站免费永久在线观看网址| 亚洲最大天堂无码精品区| 西西444www高清大胆| 国产亚洲欧洲三级片A级| 久久久2019精品| 国产精品乱码一区二区三| 国产精品hd在线播放| 亚洲中文字幕在线一区播放| 99久久国产免费-99久久国产免费| 3d欧美动漫精品xxxx| 成人一区二区三区精品| 人妻无码视频一区二区三区| 精品午夜一区二区三区久久| 久久精品国产亚洲AV品善| 精品久久久久88久久久| 安图县| 激情综合一区二区迷情校园| 元氏县| 蜜臀aⅴ国产精品久久久国产老师| 国精品午夜福利视频不卡757| 日本免费一区二区三区激情视频| 精品国产三级A在线观看网站 | 日本乱伦中文字幕| 影音先锋男人在线资源资源网| AV最新高清无码专区|